Summary notes of the LCU meeting on 05/02/2013

Present: FB, Rb, HB, RdM, LD, OD, SF, MHF, MG, PH, BH, JJ, LL, SR, MS, RT, AV, RV, FZ

Report from meetings

Analysis of IR8 aperture measurements -> PH (slides)

Pascal Hermes presented aperture measurements and studies for IR8. Recent measurements with bumps and TCT alignment were used to verify the aperture in IP8 with beams.

The apertures measured are close to the expected 24 mm. Bernard said this is important input for the discussion of the optimal crossing angle orientation. Non-linearities in the BPM response, in particular in the vertical plane, make it difficult to predict the real beam positions in the presence of crossing angles. Small differences on the level of mm are seen between the beams and transverse planes. It is planned to further improve on the modelling of the BPM non-linearities.


Specifications of orbit correctors for new triplet of HL-LHC -> RdM (slides)

Riccardo presented studies for the specification for new HL-LHC triplet orbit correctors, done in collaboration with Stephane and Massimo. Stronger correctors are required such that the separation and crossing angle bumps can be closed before the crab cavities. More strength is required in particular in the Q3 region and also in the D2-Q4 area close to the  crab cavities. The correctors should also allow for orbit corrections to compensate for misalignments up to +/- 0.5 mm. The studies also considered injection with beat* = 6m, 11, or 18m.
Helmut asked to also check on the possibility for VdM scans which are currently done without the MCBX correctors to minimise uncertainties from hysteresis effects.


AOB

None


Last update: 08-February-2013

MG & HB